   Hobo

Àå ºñ ¸í

 HOBO 4Âù³Ú ¿ÜÀå ·Î°Å

¸ð µ¨ ¸í

 H08-008-04

Á¦ Á¶ »ç

 Hobo

   
    Àåºñ »ç¾ç

 

 


»ç¾ç:HOBO 4Âù³Ú ¿ÜÀå·Î°Å






Accepts external sensors and input cables for:
Temperature
AC Current
4-20 milliamps
0 to 2.5 Volts DCOperating environment: weatherproof case, tested to NEMA 6
Accepts external sensors and input cables for temperature, AC current, 0-2.5 Volt DC and 4-20 mA
Capacity: 32,520 measurements total
User-selectable sampling interval: 0.5 seconds to 9 hours, recording times up to 1 year
Readout and relaunch with optional HOBO Shuttle
Drop-proof to 5'
Programmable start time/date
Operating range: -4¡ÆF to +158¡ÆF (-20¡ÆC to +70¡ÆC)
Access port provides easy data offload
Mounting hardware included (4 mounting screws and washers)
Size: 5.50" x 5.38" x 1.25" (140 x 137 x 32mm)
Weight: approx. 7 oz. (200 grams)
Memory modes: stop when full, wrap-around when full
Nonvolatile EEPROM memory retains data even if battery fails
Blinking LED light confirms operation
User-replaceable battery lasts 1 year
Battery level indication at launch
Time accuracy: ¡¾1 minute per week at +68¡ÆF (+20¡ÆC)
Intrinsically Safe (IS) model available for use in monitoring conditions in hazardous locations where combustible gas or dust may be a concern.***
Compliance certificate available
NIST-traceable temperature accuracy certification available

Wide range of sensors available

There are a wide range of external sensors and input cables available for the HOBO H8 Outdoor/Industrial 4-Channel External logger:

TMCx-HD water/soil temperature sensors with lengths from 6' to 50'
TMC6-HB and TMCx-HA series temperature sensors with lengths from 1' to 50'
TMC6-HC stainless steel temperature probe
Split-core AC current sensors, with ranges from 0-20 A to 0-600 A (these are not weatherproof)
0-2.5 V input cable
4-20 mA input cable
Note: Use of passive external sensors required for IS model use

External input specifications

2.5 mm jack: ground, input, switched 2.5 Volts output; ground connection is the same as PC interface connector ground
Input range: 0 to +2.5 Volts DC
Accuracy: ¡¾10 mV ¡¾1% of reading
Resolution: 10 mV (8-bit)
Output power: ¡¾2.5 Volts DC at 2 mA, active only during measurements