장 비 명

 HOBO 온도& 외장 센서

모 델 명

 H08-002-02

제 조 사

 Hobo

   
    장비 사양

 

 


사양; 옥외형 비방수형 로거







Features and specifications
Capacity: 7943 measurements total
User-selectable sampling interval: 0.5 seconds to 9 hours, recording times up to 1 year
Readout and relaunch with optional HOBO Shuttle
Internal temperature sensor on 4" wire can extend from case
Models with external input accept external sensors for temperature, AC current, 4-20 mA and 0-2.5 Volts DC
Precision components eliminate the need for user calibration
Drop-proof to 5 feet
Mounting kit included (hook/loop, magnet, and tape)
Programmable start time/date
Memory modes: stop when full, wrap-around when full
Nonvolatile EEPROM memory retains data even if battery fails
Blinking LED light confirms operation
User-replaceable battery lasts 1 year
Battery level indication at launch
Operating range: -4°F to +158°F
(-20°C to +70°C), 0 to 95% relative humidity, non-condensing, non-fogging
Time accuracy: ±1 minute per week at +68°F (+20°C)
Size/Weight: 2.4 x 1.9 x 0.8" (68 x 48 x 19 mm)/approx. 1 oz.(29 gms)
Compliance certificate available
NIST-traceable temperature accuracy certification available
Measurement specifications
Temperature (internal sensor)

Range: -4°F to +158°F (-20°C to +70°C)
Range for internal sensor when used outside of case:
-40°F to +248°F (-40°C to +120°C)
Accuracy: ±1.27°F (±0.7°C) at +70°F, see plot below
Resolution: 0.7°F (0.4°C) at +70°F
Response time still in air: 15 min. typical with sensor inside case; 1 min. typical with sensor outside case
External input accepts the following sensors:

Wide range of temperature sensors (TMCx-Hx series)
Split-core CTs for AC current (5 Models)
4-20 mA input cable (CABLE-4-20mA)
0-2.5 V DC input cable (CABLE-2.5-STEREO)
External 2.5 volt input specifications

2.5 mm jack: external input ground, input, switched 2.5 V output; external input ground connection is not the same as PC interface connection ground and should not be connected to any external ground
Input range: 0 to +2.5 Volts DC
Accuracy: ±10 mV ±1% of reading
Resolution: 10 mV (8-bit)
Out power: +2.5 Volts DC at 2 mA, active only during measurements

상담문의 담당: 박 만종
연락처:02-6679-1494 , 011-247-1494