Ȩ < Àåºñ»ó¼¼º¸±â
 


¢º ÀüüÀåºñ
¢º Campbell scientific
¢º Dranetz-BMI
¢º Audio precision
¢º Fluke
¢º Hioki
¢º Kikusui
¢º California inst.
¢º Yokogawa
¢º Pantos
¢º IWATSU
¢º LINDOS
¢º QUANTUM DATA
¢º Datataker
¢º Hobo
¢º Dynamax
¢º Greenspan
¢º Electro-metrics
¢º Chauvin Arnoux
¢º Kestrel
¢º Surge
¢º GMC
¢º NTI
¢º Astro-med
¢º Fujitsu Denso
¢º Datalogger
¢º Tektronix
¢º NF(NF Corp)
¢º Algodue
¢º Surge protector
¢º AD POWER
¢º Applent Instruments
¢º Makes Instruments

   Dranetz-BMI

Àå ºñ ¸í

 Power Quality analyzer

¸ð µ¨ ¸í

 PX5 PowerXplorer

Á¦ Á¶ »ç

 Dranetz-BMI

   
    Àåºñ »ç¾ç

 

 


»ç¾ç:
¡Ü °øÀåµîÀÇ Àü·Â °ü¸®¡¤º¸¼ö/Á¡°Ë °ü·Ã¡¤¡¤¡¤
¡¡ °¢Á¾ °øÀå, ´ë±Ô¸ð ¹éÈ­Á¡, º´¿ø, °ø°üû, À¯¿øÁöµîÀÇ Àü·Â ¶óÀÎ °ü¸®/º¸¼ö, »ý»ê ¶óÀÎÀÇ Àü·Â ¿ø´ÜÀ§ °ü¸®, »ý»ê ¼³ºñÀÇ ¿¡³ÊÁö Àý¾à °³¼±/Æò°¡¡¤º¸¼ö/°ü¸®, ISO14001ÀÇ Àü·Â °ü¸®¿¡.
¡Ü ESCO »ç¾÷¡¤°Ç¹°°ü¸®È¸»ç °ü·Ã¡¤¡¤¡¤
¡¡ °øÀ塤ºôµùµîÀÇ ¿¡³ÊÁö Àý¾à Àü·Â Á¶»ç, ¼³ºñ±â±âÀÇ Àü·Â Á¶»ç¡¤°íÁ¶ÆÄ Ç°ÁúÀÇ º¸¼ö/Á¡°Ë¿¡.
¡Ü Àü·Â °ø±Þ °ü·Ã¡¤¡¤¡¤
¡¡ Àü·Âȸ»ç µî Àü±â¸¦ °ø±Þ ÆǸÅÇÏ°í ÀÖ´Â »ç¾÷¿¡ À־ÀÇ Àü·Â »ç¿ë·® Á¶»ç, °íÁ¶ÆÄ Ç°Áú Á¶»ç¿¡.
¡Ü Àü·Â °èÅë ¼³ºñ °ü·Ã¡¤¡¤¡¤
¡¡ Àü±â º¸¾È Çùȸ, Àü±â°ø»ç, º¯Àü¼³ºñ °ü·Ã ¸ÞÀÌÄ¿ µî Àü·Â ¼³ºñÀÇ Àü·Â Á¶»ç/À¯Áö/°ü¸®, °èÅë ¿î¿ëÀÇ °íÁ¶ÆÄ Ç°ÁúÀÇ Á¤±â º¸¼ö¡¤Æ®·¯ºí Çؼ®¿¡.
¡Ü Àü±â ¼³ºñ °ü·Ã¡¤¡¤¡¤
¡¡ ¹ÝµµÃ¼ Á¦Á¶ÀåÄ¡, ÀÚµ¿ ÆǸűâ, OA±â±â, UPS ±â±â, °ø±âÁ¶Àý ±â±â, ¿ëÁ¢±âÀÇ Àü·Â ÃøÁ¤¡¤¿¡³ÊÁö Àý¾à Æò°¡ ÃøÁ¤¿¡.

The PowerXplorer integrates the most advanced feature set available in a power monitoring instrument, with an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, using a range of standard and customizable operating modes. The unique measurement capabilities of the PowerXplorer include capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize non-sinusoidal and unbalanced systems.
Features & Highlights


Eight channels, 4 voltage & 4 current
Intuitive color touch screen
Light weight ?About 4 pounds, 2 kg ?with rugged rubber boot
AC/DC applications
Samples at 256 samples/cycle
Independent voltage & current triggering, cross triggering
High-speed sampling and data capture (1 microsecond/channel)
Oscilloscope-like high speed transient detection (Dranetz 658-like and BMI-8800 like)
Detailed event characterization of RMS variations and transients
THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd
Captures IEEE 1459 parameters for non-sinusoidal and advanced power systems
Remote communications—RS-232, Ethernet or USB
Battery or AC mode
Built in UPS battery with external charger
Expanded memory up to 128 MB
Available languages ?English, Spanish, French, German, Italian, Swedish
DRAN-VIEW enabled (Windows NT, 98, ME, 2000, XP)
Measures flicker according to IEC 61000-4-15
Complies with IEEE 1159, IEC 61000-4-30 Class A and EN50160
Instrument available in 400 Hz measurement version
¢Ñ¢Ñ¢Ñ¢Ñ Àåºñ »ç¾ç PDF File Down Load Please....Click
¢Ñ¢Ñ¢Ñ¢Ñ ÇѱÛÆÇ »ç¾ç PDF File Down Load Please....Click

¢Ñ¢Ñ¢Ñ¢Ñ CT»ç¾ç PDF File Down Load Please....Click





Specifications for the PowerXplorer PX5

Measured Parameters
(4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg, 256 samples/cycle, 16 bit ADC
(4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
1 MHz High Speed Sampling, 14 bit ADC, 1%FS
Frequency Range, 10m Hz resolution, 45-65 Hz or 380-420 Hz
Phase Lock Loop - Generator tracking
Phase Lock Loop - Standard PQ mode

*****Monitoring/Compliance
IEEE 1159
IEC 61000-4-30 Class A
EN50160 Quality of Supply
Current Inrush / Energization
Voltage Fault recording
Long Term Monitoring
Continuous Data Logging w/min/max/avg

*******Power Quality Triggers
Cycle-by-cycle analysis
256 samples/cycle; 1/2 cycle RMS steps (1)
L-L, L-N, N-G RMS Variations: Sags/swells/interruptions)
RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
Waveshape Recordings (2/6/2 cycles)
Low and Medium Frequent Transients - V&I
High Frequency Transients - V&I, 3% FS trigger (1)
Harmonics Summary Parameters
Cross trigger V & I channels
RMS Event Characterization (IEEE or IEC)
Transient Event Characterization (1)

*******Distortion/Power/Energy
W, VA, VAR, TPF, DPF, Demand, Energy, etc.
IEEE 1459 Parameters of distorted and unbalanced
Harmonics/Interharmonics per IEC 1000-4-7
THD/Harmonic Spectrum (V,I,W) to 63rd
TID /Interharmonic Spectrum (V,I) to 63rd
Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
Unbalance (max. rms deviation) & sequencing components
5 User Spec Harmonics or Signaling Frequency
Vector/Arithmetic/Coincident Parameters

******Available Languages
English, French, Italian, German, Spanish, Swedish

General Specifications
Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3 cm)
Weight: 4.2 pounds (1.9 kg)
Operating Temperature: 0 -50 (32 to 122 )
Storage Temperature: -20 to 55 (4 to 131 F)
Humidity: 10 to 90% non-condensing
System Time Clock-Crystal controlled-1 second resolution
Charger /Battery Eliminator: 90-264 VAC 47-63 Hz
Display: LCD color touch screen
Memory options (must have one): 32M-128M removable compact flashcard




*******Modes of Operation
PowerXplorer users can select from a multitude of data displays such as phasors, waveforms, meters and harmonic spectrums, as well as recording options that include continuous monitoring or report-by exception, and AC and DC measurements for events lasting from a microsecond to an hour.


»ó´ã¹®ÀÇ ´ã´ç: ¹Ú ¸¸Á¾
¿¬¶ôó:02-6679-1494 , 011-247-1494

"""""Total Customer Satisfaction""""""""