PowerGuide 4400
4400Àº PX5¿Í ±¸¼ºÀÌ ºñ½ÁÇÏ¸ç ¼º´É»ó ÇÏÀ§Á¦Ç°À¸·Î °¡°Ý ´ëºñ ³ôÀº ¼º´ÉÀ¸·Î ±¸¼ºµÈ
½Ç¼ÓÇü Àü·ÂºÐ¼±â ÀÌ´Ù. 4400Àº µ¶¸³µÈ 8 ä³Î·Î ±¸¼ºµÈ 3 »ó Àü·Â ¿¡³ÊÁö ºÐ¼®±â
·Î ÷´ÜÀåºñÀÌ´Ù. »ç¿ë¹æ¹ýÀÌ ½±°í, °£´ÜÇÏ°í, ÀÛ°í °¡º±°í, Ä®¶ó ±×·¡ÇÈ µµ¾ÈµÈ
ÅÍġȸéÀ¸·Î µÇ¾îÀÖ´Ù. ȸ·Î¿Í ¼³Á¤Ä¡¸¦ °¨ÁöÇÏ¿© ÀÚµ¿À¸·Î ¼Â¾÷ÀÌ µÇ¸ç, À¯¿ëÇÑ
µ¥ÀÌÅ͸¦ ¼öÁýÇϵµ·Ï ÀÀ´äÇÑ´Ù. ÃøÁ¤ ±â°£°ú ±â´ÉÀ» ¼±ÅÃÇÏ¿© ¿©·¯°¡Áö ÀڷḦ ¼ö
ÁýÇÑ´Ù. ÃøÁ¤³»¿ëÀ¸·Î´Â ´ëÇ¥ÀûÀ¸·Î Troubleshooting, Data logging, Power
quality surveys, Harmonics,Energy & Load balancing µî¿¡ ´ëÇÏ¿© ÃøÁ¤ ºÐ¼®ÇÑ´Ù.
Ư¡ & ÀåÁ¡
8 - ä³Î, 4 voltage & 4 current °£ÆíÇÑ Ä®¶ó ÅÍÄ¡ ½ºÅ©¸° ÀÛ°í °¡º¿î Å©±â, 2 kg /w º¸È£¿ë °í¹« Ä¿¹ö AC/DC Àü¾Ð Àü·ù ÃøÁ¤¹üÀ§ Àåºñ ¼Â¾Ð¿¡ ´ëÇÑ ÀÚµ¿ ¼³Á¤ ¼ø°£ÀûÀÎ °úµµÇö»ó¿¡ ´ëÇÑ µ¶Æ¯ÇÑ ·¹Æ÷Æ® Ä«µå / Ç¥½Ã±â´É °í¼Ó ½ÜÇøµ, 256 samples/cycle °¢ ä³ÎÀÌ µ¶¸³ÀûÀ¸·Î voltage & current Æ®¸®°Å¸µ, Áßø Æ®¸®°Å¸µ Àú.Áß ÁÖÆļö Æ®·£Áö¾ðÆ® °ËÃâ ¿À½Ç·Î½ºÄÚÇÁ ±â´É THD/harmonic °íÁ¶ÆÄ & TID/interharmonics °íÁ¶ÆÄ ºÐ¼® 63rd Captures IEEE 1459 parameters for non-sinusoidal and advanced power systems ¿ø°Ý Åë½Å RS-232, Ethernet or USB Battery Àü¿ø or AC Àü¿ø »ç¿ë ³»ÀåµÈ UPS battery w/ ÃæÀü±â ÃøÁ¤ÀÚ·á ÀúÀå ¸Þ¸ð¸® 32, 64, 128 MB »ç¿ë¾ð¾î /English, Spanish, French, German, Italian, Swedish DRAN-VIEW ÀÚ·á ºÐ¼®¿ë PC Software (Windows NT, 98, ME, 2000, XP) Flicker ÃøÁ¤ according to IEC 61000-4-15 ½ÂÀÎ with IEEE 1159, IEC 61000-4-30 Class A and EN50160 ±¤¹üÀ§ÇÑ ÃøÁ¤¹üÀ§ ¹× ÃøÁ¤Ç׸ñ Crest factor, K factor, Transformer derating factor & Telephone interference factor
»ç¾ç: PowerGuide 4400 Equipped with 8 independent channels, the 3-phase PowerGuide 4400 is the only advanced power monitoring instrument to incorporate a color touch screen into its lightweight design. Automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect data. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy and load balancing. Features & Highlights
Eight channels, 4 voltage & 4 current Intuitive color touch screen Light weight ?Less than 4 pounds, 2 kg ?with rugged rubber boot AC/DC applications Automated setups for “out of the box?instrument readiness Unique “report card?annunciator that instantly characterizes events Samples at 256 samples/cycle Independent voltage & current triggering, cross triggering Capture of low-medium frequency transients THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd Remote communications—RS-232, Ethernet or USB Battery or AC mode Built in UPS battery with external charger Expanded memory up to 128 MB Available languages ?English, Spanish, French, German, Italian, Swedish DRAN-VIEW enabled (Windows NT, 98, ME, 2000, XP) Measures flicker according to IEC 61000-4-15 Measures wide range of parameters, including crest factor, K factor, transformer derating factor and telephone interference factor Complies with IEEE 1159, IEC 61000-4-30 Class A and EN50160
¢Ñ¢Ñ¢Ñ¢Ñ Àåºñ »ç¾ç PDF File Down Load Please....Click ¢Ñ¢Ñ¢Ñ¢Ñ ÇѱÛÆÇ »ç¾ç PDF File Down Load Please....Click
¢Ñ¢Ñ¢Ñ¢Ñ CT»ç¾ç PDF File Down Load Please....Click
Specifications for the PowerGuide 4400 Specifications Measured Parameters (4) differential inputs, 1-600V rms, AC/DC, 0.1% rdg , 256 samples/cycle, 16bit ADC (4) inputs with CTs 0.1-3000A rms, AC/DC, 256s/c, 0.1% rdg + CTs, 16 bit ADC Frequency range, 10mHx resolution, 45-65 Hz Phase Lock Loop - Standard PQ mode Monitoring/Compliance Modes IEEE 1159 IEC 61000-4-30 EN50160 Current Inrush / Energization Voltage Fault recording Quality of Supply (EN50160 or annunciator) Long Term Monitoring Continuous Data Logging w/min/max/avg Power Quality Triggers Cycle-by-cycle analysis 256 samples/cycle; 1/2 cycle RMS steps L-L, L-N, N-G RMS Variations: Sags/swells/interruptions) RMS Recordings V& I (x/x/x cycles) Waveform Recordings (2/6/2 cycles) Low and Medium Freq Transients - V & I Harmonics Summary Parameters Cross trigger V & I channels RMS Event Characterization (IEEE or IEC) Distortion/Power/Energy W, VA, VAR, TPF, DPF, Demand, Energy Harmonics/Interharmonics per IEC 1000-4-7 THD/Harmonic Spectrum (V,I,W) to 63rd TID/Interharm. Spectrum (V,I) to 63rd Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt) CF, KF, TDF, TIF Unbalance (rms dev. & sequencing components) General Specifications Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3 cm) Weight: 3.8 pounds(1.8 kg) Operating Temperature: 0 -50 (32 to 122 ) Storage Temperature: -20 to 55 (4 to 131 F) Humidity: 10 to 90% non-condensing System Time Clock: Crysal controlled, 1 second resolution Charger /Battery Eliminator: 90-264 VAC 47-63 Hz Display: LCD color touch screen Memory options (must have one): 32M-128M removable compact flashcard
¡Ü °øÀåµîÀÇ Àü·Â °ü¸®¡¤º¸¼ö/Á¡°Ë °ü·Ã¡¤¡¤¡¤ ¡¡ °¢Á¾ °øÀå, ´ë±Ô¸ð ¹éÈÁ¡, º´¿ø, °ø°üû, À¯¿øÁöµîÀÇ Àü·Â ¶óÀÎ °ü¸®/º¸¼ö, »ý»ê ¶óÀÎÀÇ Àü·Â ¿ø´ÜÀ§ °ü¸®, »ý»ê ¼³ºñÀÇ ¿¡³ÊÁö Àý¾à °³¼±/Æò°¡¡¤º¸¼ö/°ü¸®, ISO14001ÀÇ Àü·Â °ü¸®¿¡. ¡Ü ESCO »ç¾÷¡¤°Ç¹°°ü¸®È¸»ç °ü·Ã¡¤¡¤¡¤ ¡¡ °øÀ塤ºôµùµîÀÇ ¿¡³ÊÁö Àý¾à Àü·Â Á¶»ç, ¼³ºñ±â±âÀÇ Àü·Â Á¶»ç¡¤°íÁ¶ÆÄ Ç°ÁúÀÇ º¸¼ö/Á¡°Ë¿¡. ¡Ü Àü·Â °ø±Þ °ü·Ã¡¤¡¤¡¤ ¡¡ Àü·Âȸ»ç µî Àü±â¸¦ °ø±Þ ÆǸÅÇÏ°í ÀÖ´Â »ç¾÷¿¡ ÀÖ¾î¼ÀÇ Àü·Â »ç¿ë·® Á¶»ç, °íÁ¶ÆÄ Ç°Áú Á¶»ç¿¡. ¡Ü Àü·Â °èÅë ¼³ºñ °ü·Ã¡¤¡¤¡¤ ¡¡ Àü±â º¸¾È Çùȸ, Àü±â°ø»ç, º¯Àü¼³ºñ °ü·Ã ¸ÞÀÌÄ¿ µî Àü·Â ¼³ºñÀÇ Àü·Â Á¶»ç/À¯Áö/°ü¸®, °èÅë ¿î¿ëÀÇ °íÁ¶ÆÄ Ç°ÁúÀÇ Á¤±â º¸¼ö¡¤Æ®·¯ºí Çؼ®¿¡. ¡Ü Àü±â ¼³ºñ °ü·Ã¡¤¡¤¡¤ ¡¡ ¹ÝµµÃ¼ Á¦Á¶ÀåÄ¡, ÀÚµ¿ ÆǸűâ, OA±â±â, UPS ±â±â, °ø±âÁ¶Àý ±â±â, ¿ëÁ¢±âÀÇ Àü·Â ÃøÁ¤¡¤¿¡³ÊÁö Àý¾à Æò°¡ ÃøÁ¤¿¡.
»ó´ã¹®ÀÇ ´ã´ç: ¹Ú ¸¸Á¾ ¿¬¶ôó:02-6679-1494 , 011-247-1494
"""""Total Customer Satisfaction""""""""
|
|
|
|