   Campbell scientific

Àå ºñ ¸í

 Wind seed Monitor ¼¾¼­

¸ð µ¨ ¸í

 05103 dzÇâdz¼Ó°è

Á¦ Á¶ »ç

 Campbell scientific

   
    Àåºñ »ç¾ç

 

 


»ç¾ç:

dzÇâ/dz¼Ó ¼¾¼­(05103)
-Á¦ Á¶ »ç : RM-Young
-¼¾¼­Å¸ÀÔ : ÇÁ·ÎÆç·¯½Ä ÀÏüÇü
-ÃøÁ¤¹üÀ§ : dz¼Ó(0~60m/s) / dzÇâ(0~360 degree)





¢Ñ¢Ñ¢Ñ¢Ñ (Ä«´Ù·Î±×ÀÚ·á´Ù¿î ¹Þ±â)....Click

¢Ñ¢Ñ¢Ñ¢Ñ (Ä«´Ù·Î±×ÀÚ·á´Ù¿î ¹Þ±â)....Click

Specifications;

Wind Monitor (Model 05103) : Wind Monitor-AQ (Model 05305)
Wind speed
Range: 0-134 mph (0-60 m s-1) : 0-90 mph (0-40 m s-1)
Accuracy: ¡¾0.6 mph (¡¾0.3 m s-1) : ¡¾0.4 mph (¡¾0.2 m s-1)
Starting threshold: 2.2 mph (1.0 m s-1) : 0.9 mph (0.4 m s-1)
Gust survival: 220 mph (100 m s-1) : 100 mph (45 m s-1)
Distance constant
(63% recovery): 8.9 ft (2.7 m) : 6.9 ft (2.1 m)
Output: ac voltage (3 pulses/ ac voltage (3 pulses/
revolution) 1800 rpm revolution) 1800 rpm
(90 Hz) - 19.7 mph : (90 Hz) - 20.6 mph
(8.8 ms-1) : (9.2 ms-1)
Wind direction
Electrical range: 0-360¡Æ mechanical, Same
355¡Æ electrical (5¡Æ open)
Accuracy: ¡¾3¡Æ ¡¾3¡Æ
Starting threshold
at 10¡Æ displacement: 2.0 mph (0.9 m s-1) : 1.0 mph (0.5 m s-1)
at 5¡Æ displacement: 2.9 mph (1.3 m s-1) : 1.6 mph (0.7 m s-1)
Delay distance
(50% recovery): 4.3 ft (1.3 m) : 3.9 ft (1.2 m)
Damping ratio: 0.25 0.45
Damped natural wavelength: 24.3 ft (7.4 m) : 16.1 ft (4.9 m)
Undamped natural
wavelength: 23.6 ft (7.2 m) : 14.4 ft (4.4 m)
Output: Analog dc voltage from Same
potentiometer - resistance
10 K§Ù, linearity 0.25%,
life expectancy 50 million
revolutions.
Power Switched excitation Same
voltage is supplied
by the datalogger.
Ordering Information 05103-L11 = 11' lead length for CM6/10 05305-L11 = 11' lead length for CM6/10
tripod and UT10 10-foot (3 m) tower tripods and UT10 10-foot (3 m) tower
05103-L23 = 23¡¯ lead length for UT20 05305-L23 = 23¡¯ lead length for UT20
20-foot (7 m) tower 20-foot (7 m) tower
05103-L34 = 34' lead length for 05305-L34 = 34¡¯ lead length for
UT30 30-foot (10 m) tower UT30 30-foot (10 m) tower
Operating Temperature -50¡Æ to +50¡ÆC, assuming non-riming -50¡Æ to +50¡ÆC, assuming non-riming
conditions conditions
Dimensions
Overall: 14.6¡± H x 21.7¡± L 15.0¡± H x 25.6¡° L
(37 cm x 55 cm) (38 cm x 65 cm)
Main housing (diameter): 2.0¡° (5 cm) Same
Propeller (diameter): 7.1¡± (18 cm) 7.9¡± (20 cm)
Mounting (diameter): 1.34¡± (34 mm) Same
(standard 1.0¡± pipe)
Weight (shipping approx.) 3.2 lbs (5.5 lbs); 1.5 kg (2.3 kg) 2.5 lbs (5.5 lbs); 1.1 kg (2.3 kg)
Manufactured by RM Young (Traverse City, MI) and cabled by Campbell Scientific for use with our dataloggers.