   Hioki

Àå ºñ ¸í

 Power Analyzer

¸ð µ¨ ¸í

 3196

Á¦ Á¶ »ç

 Hioki

   
    Àåºñ »ç¾ç

 

 


»ç¾ç;
Measurement;

lines Single-phase/two-wires, Single-phase/three-wires, Three-phase/three-wires, Three-phase/four-wires

Monitor and record the quality of power to analyze the cause of trouble when it occurs !

The 3196 is your most reliable and complete instrument for power quality troubleshooting !
Measure power factor

Sags

Swells

Flicker

Transients
Harmonics to the 50th

High Frequency transient

Detection and waveform display

Four current and Four voltage channels


Let the HIOKI 3196 see what you have been missing.

Measurement items;
Impulsive voltage quality:Transient overvoltage (Impulse), RMS voltage quality:Voltage swell, Voltage dips, Voltage interruption, Power quality:Frequency, Voltage, Current, Current peak, Active/Reactive apparent power, Power factor (displaced power factor), Three phase quality:Voltage unbalance ratio, Current unbalance ratio, Harmonic quality (Up to 50th order):Harmonic voltage, Harmonic current, Harmonic power, Inter-harmonic voltage, Inter-harmonic current, Harmonic phase angle, Total harmonic voltage distortion, Total inter-harmonic current distortion (THD-F, THD-R), Total inter-harmonic voltage distortion ratio, Total inter-harmonic current distortion ratio (THD-F, THD-R), K factor, Flicker:Measures delta- V10 flicker (Japanese domestic), or UIE flicker [Pst, Plt] (international standards),
Measurement ranges;
Voltage ch1 to ch3: 150.00 to 600.00 V AC rms-3 ranges, ch4: 60.000 to 600.00 V AC rms-4 ranges, or 60.000/600.00 V DC-2 ranges, Current (When using 100 A sensor): 50.000/100.00 A AC rms-2 ranges, Current (When using 500 A sensor): 50.000/500.00 A AC rms-2 ranges, Power: Combination pattern of voltage and current ranges
Measurement method;
Transient overvoltage: 2 mega-sampling/sec, Harmonic wave: 2048 point (10 cycle at 50 Hz, or 12 cycle at 60 Hz), Other effective value: 256 point/one cycle

Memory; capacity 13 MB
Interface;
PC card slot (flash ATA/528 MB or less), RS-232C, LAN (10BASE-T)
Power supply;
12 V DC output 9458 AC ADAPTER (Universal 100 to 240 V AC, 50/60 Hz), or 9459 BATTERY PACK (7.2 V/2450 m Ah Ni-MH)
Dimensions;, mass 298 mm(11.73 in)W ¡¿ 215 mm(8.46 in)H ¡¿ 67 mm(2.64 in) D, 2 kg (70.5 oz)...without battery
Accessories;
Voltage cord (one set), 9458 AC ADAPTER (1), 9459 BATTERY PACK (1), shoulder strap (1), LAN connector cover (1), marking label (1)


¢Ñ¢Ñ¢Ñ¢Ñ PDF File Down Load(3196 ½ºÆåÀÚ·á´Ù¿î ¹Þ±â)


»ó´ã¹®ÀÇ ´ã´ç: ¹Ú ¸¸Á¾
¿¬¶ôó:02-6679-1494 , 010-5247-1494

"""""Total Customer Satisfaction""""""""