Audio precision
|
|
Àå ºñ ¸í
|
Switchers
|
¸ð
µ¨ ¸í
|
SWR 1222
|
Á¦
Á¶ »ç
|
Audio precision
|
|
|
|
|
|
Àåºñ »ç¾ç |
|
|
»ç¾ç;
Expands System capability up to 192 inputs & outputs Balanced (XLR) and Unbalanced (BNC) connector versions available Patch point version inserts test generator and analyzer at patch point Crosstalk < -140 dB @ 20 kHz, balanced
ELECTRICAL CHARACTERISTICS Max Voltage Rating 200 Vpk, 160 Vrms Max Signal Power 1 30 Watts or 1 Ampere, whichever is greater Crosstalk 2 Balanced 600 Load 20 kHz -140 dB 100 kHz -126 dB Unbalanced 600 Load 20 kHz -120 dB 100 kHz -106 dB Series Resistance Typically <0.3 ohms per side Shunt Capacitance Typically <90 pF, each side to ground GENERAL CHARACTERISTICS Power Requirements 100/120/230/240 Vac (-10%/+6%) 50-60 Hz, 15 VA max Temperature Range Operating 0¡ÆC to +50¡ÆC Storage -40¡ÆC to +75¡ÆC Humidity 90% RH to at least +40¡ÆC, (non-condensing) Dimensions 16.5 x 1.75 x 10.5 inches [41.9 x 4.4 x 26.7 cm] Weight Approximately 9.9 Ibs [4.5 kg] REGULATORY COMPLIANCES EMC 89/336/EEC; CISPR 22 (class B); FCC 15 subpart J (class B) Safety 73/23/EEC; EC1010 -1 (including amendments 1 & 2) NOTES 1. Relay contact resistance degrades rapidly with increasing switched power. For maximum relay life (typically 20 x 106 operations) Audio Precision recommends limiting the maximum switched signal power to 5 Watts or 200 mA. 2. Measured between any two selectable channels into the specified load impedance. SWR-2122P (patch point switcher) crosstalk from the interrupted input to output is typically 70 dB to 20 kHz. Mounting
All switchers occupy one rack unit of height (1.75 inches). They are provided with bottom feet for table top use. They may be rack mounted with an optional rack mount adapter available from Audio Precision (order number RAK-212). These adapters allow either conventional flush front mounting or set-back mounting to prevent the front connectors from protruding from the rack.
For further information, including DIP switch settings, see the Switchers Setup and Installation Guide, 8211.0023.
|
|
|
|
|