                                     PowerGuide 4400        
            4400Àº PX5¿Í ±¸¼ºÀÌ ºñ½ÁÇÏ¸ç ¼º´É»ó ÇÏÀ§Á¦Ç°À¸·Î °¡°Ý ´ëºñ ³ôÀº ¼º´ÉÀ¸·Î ±¸¼ºµÈ
      ½Ç¼ÓÇü  Àü·ÂºÐ¼±â ÀÌ´Ù. 4400Àº µ¶¸³µÈ 8 ä³Î·Î ±¸¼ºµÈ 3 »ó Àü·Â ¿¡³ÊÁö ºÐ¼®±â
     ·Î ÷´ÜÀåºñÀÌ´Ù. »ç¿ë¹æ¹ýÀÌ ½±°í, °£´ÜÇϰí, ÀÛ°í °¡º±°í, Ä®¶ó ±×·¡ÇÈ µµ¾ÈµÈ 
     ÅÍġȸéÀ¸·Î µÇ¾îÀÖ´Ù. ȸ·Î¿Í ¼³Á¤Ä¡¸¦ °¨ÁöÇÏ¿© ÀÚµ¿À¸·Î ¼Â¾÷ÀÌ µÇ¸ç, À¯¿ëÇÑ
     µ¥ÀÌÅ͸¦ ¼öÁýÇϵµ·Ï ÀÀ´äÇÑ´Ù. ÃøÁ¤ ±â°£°ú ±â´ÉÀ» ¼±ÅÃÇÏ¿© ¿©·¯°¡Áö ÀڷḦ ¼ö
     ÁýÇÑ´Ù.   ÃøÁ¤³»¿ëÀ¸·Î´Â ´ëÇ¥ÀûÀ¸·Î Troubleshooting, Data logging, Power 
     quality surveys, Harmonics,Energy & Load balancing µî¿¡ ´ëÇÏ¿© ÃøÁ¤ ºÐ¼®ÇÑ´Ù.
     Ư¡ & ÀåÁ¡ 
  8 - ä³Î, 4 voltage & 4 current  °£ÆíÇÑ Ä®¶ó ÅÍÄ¡ ½ºÅ©¸°  ÀÛ°í °¡º¿î Å©±â, 2 kg /w º¸È£¿ë °í¹« Ä¿¹ö  AC/DC Àü¾Ð Àü·ù ÃøÁ¤¹üÀ§  Àåºñ ¼Â¾Ð¿¡ ´ëÇÑ ÀÚµ¿ ¼³Á¤  ¼ø°£ÀûÀÎ °úµµÇö»ó¿¡ ´ëÇÑ µ¶Æ¯ÇÑ ·¹Æ÷Æ® Ä«µå / Ç¥½Ã±â´É  °í¼Ó ½ÜÇøµ, 256 samples/cycle  °¢ ä³ÎÀÌ µ¶¸³ÀûÀ¸·Î voltage & current Æ®¸®°Å¸µ, Áßø Æ®¸®°Å¸µ  Àú.Áß Á֯ļö Æ®·£Áö¾ðÆ® °ËÃâ  ¿À½Ç·Î½ºÄÚÇÁ ±â´É  THD/harmonic °íÁ¶ÆÄ & TID/interharmonics °íÁ¶ÆÄ ºÐ¼® 63rd  Captures IEEE 1459 parameters for non-sinusoidal and advanced power systems  ¿ø°Ý Åë½Å RS-232, Ethernet or USB  Battery Àü¿ø or AC Àü¿ø »ç¿ë  ³»ÀåµÈ UPS battery w/ ÃæÀü±â  ÃøÁ¤ÀÚ·á ÀúÀå ¸Þ¸ð¸® 32, 64, 128 MB  »ç¿ë¾ð¾î /English, Spanish, French, German, Italian, Swedish  DRAN-VIEW ÀÚ·á ºÐ¼®¿ë PC Software (Windows NT, 98, ME, 2000, XP)  Flicker ÃøÁ¤ according to IEC 61000-4-15  ½ÂÀÎ with IEEE 1159, IEC 61000-4-30 Class A and EN50160  ±¤¹üÀ§ÇÑ ÃøÁ¤¹üÀ§ ¹× ÃøÁ¤Ç׸ñ Crest factor, K factor, Transformer derating factor & Telephone interference factor
  »ç¾ç: PowerGuide 4400 Equipped with 8 independent channels, the 3-phase PowerGuide 4400 is the only advanced power monitoring instrument to incorporate a color touch screen into its lightweight design. Automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect data. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy and load balancing.  Features & Highlights
 
  Eight channels, 4 voltage & 4 current  Intuitive color touch screen  Light weight ?Less than 4 pounds, 2 kg ?with rugged rubber boot  AC/DC applications  Automated setups for “out of the box?instrument readiness  Unique “report card?annunciator that instantly characterizes events  Samples at 256 samples/cycle  Independent voltage & current triggering, cross triggering  Capture of low-medium frequency transients  THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd  Remote communications—RS-232, Ethernet or USB  Battery or AC mode  Built in UPS battery with external charger  Expanded memory up to 128 MB  Available languages ?English, Spanish, French, German, Italian, Swedish  DRAN-VIEW enabled (Windows NT, 98, ME, 2000, XP)  Measures flicker according to IEC 61000-4-15  Measures wide range of parameters, including crest factor, K factor, transformer derating factor and telephone interference factor  Complies with IEEE 1159, IEC 61000-4-30 Class A and EN50160
 
   ¢Ñ¢Ñ¢Ñ¢Ñ Àåºñ »ç¾ç PDF File Down Load Please....Click 
   ¢Ñ¢Ñ¢Ñ¢Ñ ÇÑ±ÛÆÇ »ç¾ç PDF File Down Load Please....Click 
 
   ¢Ñ¢Ñ¢Ñ¢Ñ CT»ç¾ç PDF File Down Load Please....Click 
 
 
  
   Specifications for the PowerGuide 4400 Specifications  Measured Parameters  (4) differential inputs, 1-600V rms, AC/DC, 0.1% rdg , 256 samples/cycle, 16bit ADC  (4) inputs with CTs 0.1-3000A rms, AC/DC, 256s/c, 0.1% rdg + CTs, 16 bit ADC  Frequency range, 10mHx resolution, 45-65 Hz  Phase Lock Loop - Standard PQ mode     Monitoring/Compliance Modes  IEEE 1159  IEC 61000-4-30  EN50160  Current Inrush / Energization  Voltage Fault recording  Quality of Supply (EN50160 or annunciator)  Long Term Monitoring  Continuous Data Logging w/min/max/avg     Power Quality Triggers  Cycle-by-cycle analysis  256 samples/cycle; 1/2 cycle RMS steps  L-L, L-N, N-G RMS Variations: Sags/swells/interruptions)  RMS Recordings V& I (x/x/x cycles)  Waveform Recordings (2/6/2 cycles)  Low and Medium Freq Transients - V & I  Harmonics Summary Parameters  Cross trigger V & I channels  RMS Event Characterization (IEEE or IEC)     Distortion/Power/Energy  W, VA, VAR, TPF, DPF, Demand, Energy  Harmonics/Interharmonics per IEC 1000-4-7  THD/Harmonic Spectrum (V,I,W) to 63rd  TID/Interharm. Spectrum (V,I) to 63rd  Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)  CF, KF, TDF, TIF  Unbalance (rms dev. & sequencing components)     General Specifications  Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3 cm)  Weight: 3.8 pounds(1.8 kg)  Operating Temperature: 0 -50 (32 to 122 )  Storage Temperature: -20 to 55 (4 to 131 F)  Humidity: 10 to 90% non-condensing  System Time Clock: Crysal controlled, 1 second resolution  Charger /Battery Eliminator: 90-264 VAC 47-63 Hz  Display: LCD color touch screen  Memory options (must have one): 32M-128M removable compact flashcard 
  ¡Ü °øÀåµîÀÇ Àü·Â °ü¸®¡¤º¸¼ö/Á¡°Ë °ü·Ã¡¤¡¤¡¤  ¡¡ °¢Á¾ °øÀå, ´ë±Ô¸ð ¹éÈÁ¡, º´¿ø, °ø°üû, À¯¿øÁöµîÀÇ Àü·Â ¶óÀÎ °ü¸®/º¸¼ö, »ý»ê ¶óÀÎÀÇ Àü·Â ¿ø´ÜÀ§ °ü¸®, »ý»ê ¼³ºñÀÇ ¿¡³ÊÁö Àý¾à °³¼±/Æò°¡¡¤º¸¼ö/°ü¸®, ISO14001ÀÇ Àü·Â °ü¸®¿¡.  ¡Ü ESCO »ç¾÷¡¤°Ç¹°°ü¸®È¸»ç °ü·Ã¡¤¡¤¡¤  ¡¡ °øÀ塤ºôµùµîÀÇ ¿¡³ÊÁö Àý¾à Àü·Â Á¶»ç, ¼³ºñ±â±âÀÇ Àü·Â Á¶»ç¡¤°íÁ¶ÆÄ ǰÁúÀÇ º¸¼ö/Á¡°Ë¿¡.  ¡Ü Àü·Â °ø±Þ °ü·Ã¡¤¡¤¡¤  ¡¡ Àü·Âȸ»ç µî Àü±â¸¦ °ø±Þ ÆÇ¸ÅÇϰí ÀÖ´Â »ç¾÷¿¡ ÀÖ¾î¼ÀÇ Àü·Â »ç¿ë·® Á¶»ç, °íÁ¶ÆÄ ǰÁú Á¶»ç¿¡.  ¡Ü Àü·Â °èÅë ¼³ºñ °ü·Ã¡¤¡¤¡¤  ¡¡ Àü±â º¸¾È Çùȸ, Àü±â°ø»ç, º¯Àü¼³ºñ °ü·Ã ¸ÞÀÌÄ¿ µî Àü·Â ¼³ºñÀÇ Àü·Â Á¶»ç/À¯Áö/°ü¸®, °èÅë ¿î¿ëÀÇ °íÁ¶ÆÄ ǰÁúÀÇ Á¤±â º¸¼ö¡¤Æ®·¯ºí ÇØ¼®¿¡.  ¡Ü Àü±â ¼³ºñ °ü·Ã¡¤¡¤¡¤  ¡¡ ¹ÝµµÃ¼ Á¦Á¶ÀåÄ¡, ÀÚµ¿ ÆÇ¸Å±â, OA±â±â, UPS ±â±â, °ø±âÁ¶Àý ±â±â, ¿ëÁ¢±âÀÇ Àü·Â ÃøÁ¤¡¤¿¡³ÊÁö Àý¾à Æò°¡ ÃøÁ¤¿¡. 
  »ó´ã¹®ÀÇ ´ã´ç: ¹Ú ¸¸Á¾ ¿¬¶ôó:02-6679-1494 , 011-247-1494
  """""Total Customer Satisfaction""""""""   
                                         
                                     |     
                                       
                                       
                                     
                               |     
                                 
                                 
                               
                         |     
                           
                           
                         
                   |